EasyManua.ls Logo

Daikin FCQ50B7V1 - Page 296

Daikin FCQ50B7V1
390 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Disassembly and Maintenance ESIE05-04
5–46 Part 5 – Disassembly and Maintenance
3
1
5
5
1.12.3 Removal of Decoration Panel
Warning Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work.
Procedure:
Step Procedure Points
1 Removing the decoration
panel
1 Remove the switch box
cover and disconnect the
connector of swing motor
from the harness
connector of electric
parts.
2 Check that the
provisional hanger is in
the position where it can
be engaged with the hook
of switch box.
(S2636)
(S2637
)
Provisional hanger
Hook of switch box
(S2638)

Table of Contents

Other manuals for Daikin FCQ50B7V1

Related product manuals