Disassembly and Maintenance ESIE05-04
5–88 Part 5 – Disassembly and Maintenance
3
1
5
5
4 Cut off the tie-wrap of the
glass tube cover over the
fan motor connector.
Slide the glass tube and
get the connector
exposed.
Q Aconnectors
Connector (1) handles high
voltage (220-240 V), so be
sure to turn of the power
supply before disconnecting.
5 Disconnect the 2 fan
motor connecting
connectors.
6 Remove the 2 fan motor
fasteners.
7 Remove the fan motor.
Q Finally reconnect the fan
motor connector, cover it with
the glass tube and secure it
with the tie-wrap.
Step Procedure Points