What to do if Daikin FCQG140FVEB Air Conditioner detects multiple master units?
- GGary GordonAug 9, 2025
If your Daikin Air Conditioner detects multiple master units, connect the remote controller to only one indoor unit.
What to do if Daikin FCQG140FVEB Air Conditioner detects multiple master units?
If your Daikin Air Conditioner detects multiple master units, connect the remote controller to only one indoor unit.
What to do if Daikin Air Conditioner has gas shortage due to clogging in refrigerant piping?
If you suspect clogging in the refrigerant piping system of your Daikin Air Conditioner, check for a failure to open the stop valve and any clogging within the refrigerant system.
What does excess indoor units connected error mean on Daikin FCQG140FVEB?
This error will be displayed if five or more indoor units are connected to your Daikin Air Conditioner.
Why does my Daikin Heat Pump emit an odor?
If your Daikin Heat Pump emits an odor, it's likely due to room smells and cigarette odors that have accumulated inside the indoor unit. To resolve this, the inside of the indoor unit must be cleaned.
Power Supply | 3 Phase, 380-415V, 50Hz |
---|---|
Heating Capacity | 16.0 kW |
Refrigerant | R410A |
Airflow Rate | 720 m3/h |
Sound Pressure Level (Indoor) | 34 dBA |
Net Weight (Indoor Unit) | 9.5 kg |
Air Flow (Indoor) | 720 m3/h |
Essential safety precautions to be read before conducting any repair work.
Explanation of icons used to attract reader's attention to specific information.
Introduction to the service manual for the RZQG-L & RZQSG-L series Heat Pump System.
Lists the model names for indoor and outdoor units, including combination possibilities.
Provides visual outlooks of the different outdoor units available.
Details the operating temperature ranges for Smart and Classic models in cooling/heating.
Covers applicable models, names, functions, settings, and modes for wired controllers.
Details applicable models, names, functions, and settings for wireless controllers.
Explains how to enter and use service modes for displaying data and settings.
Describes how to use the inspection mode for checking unit status and model codes.
Explains the function of key components and thermistors in the RZQG-L9V1.
Illustrates the operational flow for cooling/dry and heating modes.
Details indoor and outdoor unit functions like temperature control and protection.
Guidelines and precautions for performing test operations after installation.
Instructions for changing indoor unit settings using wired and wireless controllers.
Details on using DIP switches and BS buttons for outdoor unit settings.
Describes methods for forced operation and emergency control of the unit.
Overview of essential inspections to perform during maintenance.
Guides to diagnose and resolve issues based on observed symptoms.
Troubleshooting based on LED status on indoor and outdoor unit PCBs.
Guides for diagnosing errors and abnormalities displayed on the remote controller.
Provides piping diagrams for the RZQG-L9V1 model.
Includes wiring diagrams for the outdoor unit (RZQG71L, RZQG100-140L).
Presents thermodynamic data for R-410A refrigerant.
Step-by-step instructions for removing and mounting the switchbox components.