Service Manual
GQI-Eco Series
Heat Pump R-410A 50Hz
Smart RZQG71~140L9V1
RZQG71~125L9Y1 / RZQG140LY1
Classic RZQSG71L3V1 / RZQSG100~140L9V1
RZQSG100~125L8Y1 / RZQSG140LY1
ESIE15-13B

Table of Contents

Other manuals for Daikin FCQG140FVEB

Questions and Answers:

Daikin FCQG140FVEB Specifications

General IconGeneral
Power Supply3 Phase, 380-415V, 50Hz
Heating Capacity16.0 kW
RefrigerantR410A
Airflow Rate720 m3/h
Sound Pressure Level (Indoor)34 dBA
Net Weight (Indoor Unit)9.5 kg
Air Flow (Indoor)720 m3/h

Summary

Introduction

Safety Cautions

Essential safety precautions to be read before conducting any repair work.

Used Icons

Explanation of icons used to attract reader's attention to specific information.

Preface

Introduction to the service manual for the RZQG-L & RZQSG-L series Heat Pump System.

Part 1 - General Information

Model Names of Indoor / Outdoor Units

Lists the model names for indoor and outdoor units, including combination possibilities.

Outlook Outdoor Units

Provides visual outlooks of the different outdoor units available.

Operating Range

Details the operating temperature ranges for Smart and Classic models in cooling/heating.

Part 2 - Remote Controller

Wired Remote Controller

Covers applicable models, names, functions, settings, and modes for wired controllers.

Wireless Remote Controller

Details applicable models, names, functions, and settings for wireless controllers.

Service Mode

Explains how to enter and use service modes for displaying data and settings.

Inspection Mode

Describes how to use the inspection mode for checking unit status and model codes.

Part 3 - Function and Control

Function of Main Components and Thermistors

Explains the function of key components and thermistors in the RZQG-L9V1.

Operation Flow Chart

Illustrates the operational flow for cooling/dry and heating modes.

Function Details

Details indoor and outdoor unit functions like temperature control and protection.

Part 4 - Field Setting

Test Operation

Guidelines and precautions for performing test operations after installation.

Field Setting from Remote Controller

Instructions for changing indoor unit settings using wired and wireless controllers.

Field Setting from Outdoor Unit PCB

Details on using DIP switches and BS buttons for outdoor unit settings.

Emergency Operation

Describes methods for forced operation and emergency control of the unit.

Part 5 - Service Diagnosis

Maintenance Inspection

Overview of essential inspections to perform during maintenance.

Symptom-based Troubleshooting

Guides to diagnose and resolve issues based on observed symptoms.

Troubleshooting by LED Indications

Troubleshooting based on LED status on indoor and outdoor unit PCBs.

Troubleshooting by Remote Controller

Guides for diagnosing errors and abnormalities displayed on the remote controller.

Part 6 - Appendix

Piping Diagrams

Provides piping diagrams for the RZQG-L9V1 model.

Wiring Diagrams

Includes wiring diagrams for the outdoor unit (RZQG71L, RZQG100-140L).

Thermodynamic Characteristic of R-410A

Presents thermodynamic data for R-410A refrigerant.

Removing the Switchbox

Step-by-step instructions for removing and mounting the switchbox components.