What to do if Daikin FCQG60FVEB detects multiple master units?
- BBrent PinedaAug 9, 2025
If your Daikin Air Conditioner detects multiple master units, connect the remote controller to only one indoor unit.
What to do if Daikin FCQG60FVEB detects multiple master units?
If your Daikin Air Conditioner detects multiple master units, connect the remote controller to only one indoor unit.
What to do if Daikin FCQG60FVEB Air Conditioner has gas shortage due to clogging in refrigerant piping?
If you suspect clogging in the refrigerant piping system of your Daikin Air Conditioner, check for a failure to open the stop valve and any clogging within the refrigerant system.
What does excess indoor units connected error mean on Daikin Air Conditioner?
This error will be displayed if five or more indoor units are connected to your Daikin Air Conditioner.
Why does my Daikin Heat Pump emit an odor?
If your Daikin Heat Pump emits an odor, it's likely due to room smells and cigarette odors that have accumulated inside the indoor unit. To resolve this, the inside of the indoor unit must be cleaned.
Type | Ceiling Cassette |
---|---|
Cooling Capacity | 6.0 kW |
Refrigerant | R-32 |
Noise Level (Outdoor) | 50 dB(A) |
Power Supply | 220-240V / 1 Phase / 50Hz |
Lists functions of outdoor and indoor units for cooling operation.
Lists functions of outdoor and indoor units for heat pump operation.
Technical specifications for cooling outdoor and indoor units.
Technical specifications for heat pump outdoor and indoor units.
Wiring diagrams and connector details for outdoor units.
Wiring diagrams and connector details for various indoor units.
Wiring diagrams and connector details for wired remote controllers.
Details on various functions and controls for RA indoor units.
Details on various functions and controls for SA indoor units.
Explains the function of different thermistors used in the system.
Details on control specifications and logic for system operation.
Overview of the air conditioning system setup and user guidance.
Manual contents and reference pages for RA indoor units.
Manual contents and reference pages for SA indoor units.
Troubleshooting indoor and outdoor unit errors indicated by LEDs.
Lists common problem symptoms and their corresponding measures.
Detailed procedures for performing service checks.
Lists error codes displayed on the remote controller and their descriptions.
Troubleshooting guide for RA indoor units covering various component issues.
Troubleshooting guide for SA indoor units covering various component issues.
Troubleshooting guide for outdoor unit issues including refrigerant and electrical faults.
Procedures for checking various components like thermistors and motors.
Step-by-step instructions for removing parts of outdoor units (40-75 Class).
Step-by-step instructions for removing parts of outdoor units (80/90 Class).
Procedure for pump down operation before unit relocation or disposal.
Details on how to perform forced cooling and heating operations.
Procedure for checking wiring errors in the system.
Procedure for conducting trial operation of the air conditioner.
Explains how to configure field settings for various unit components.
Guidelines for applying silicon grease to heat-radiating components.
Schematic diagrams illustrating the refrigerant piping for various models.
Schematic diagrams illustrating the electrical wiring for various units.