10 | Maintenance and service
Installer and user reference guide
35
FDA125A5VEB
Split system air conditioners
4P495031-1B – 2022.10
Turn off the power. The user interface display disappears. When the main power
is turned on, the air conditioner will use some power, even if it is not operating.
Clean the air filter and the casing of the indoor unit (see "10.2Cleaning the air
filter and air outlet" [4 33]). Make sure to install cleaned air filters back in the
same position.
Remove the batteries from the user interface (if applicable).
10.4 Maintenance after a long stop period
E.g., at the beginning of the season.
Check and remove everything that might be blocking inlet and outlet vents of
indoor units and outdoor units.
Check if the earth is connected properly.
Check if there is somewhere a broken wire. Contact your dealer in case of
problems.
Clean the air filter and the casing of the indoor unit (see "10.2Cleaning the air
filter and air outlet" [4 33]). Make sure to install cleaned air filters back in the
same position.
Turn on the power at least 6 hours before operating the unit in order to ensure
smoother operation. As soon as the power is turned on, the user interface
display appears.
Insert batteries in the user interface (if applicable).
10.5 About the refrigerant
This product contains fluorinated greenhouse gases. Do NOT vent gases into the
atmosphere.
Refrigerant type: R32
Global warming potential (GWP) value: 675
Refrigerant type: R410A
Global warming potential (GWP) value: 2087.5
NOTICE
Applicable legislation on fluorinated greenhouse gases requires that the refrigerant
charge of the unit is indicated both in weight and CO
2
equivalent.
Formula to calculate the quantity in CO
2
equivalent tonnes: GWP value of the
refrigerant × total refrigerant charge [in kg]/1000
Contact your installer for more information.
WARNING: MILDLY FLAMMABLE MATERIAL
The R32 refrigerant (if applicable) in this unit is mildly flammable. Refer to the
outdoor unit specifications for the type of refrigerant to be used.