EasyManua.ls Logo

Daikin FLKS25BAVMB - Page 143

Daikin FLKS25BAVMB
232 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Outdoor Unit - RK(X)S25/35E2V1B SiENBE05-722_A
132 Removal Procedure
3
Remove the 2 screws
and lift the bell mouth to
unfasten the hooks.
4
Remove the bell mouth.
5
Open the hooks and
release the fan motor
lead wire.
When reassembling, put the
fan motor lead wire through
the back of the fan motor (so
as not to be entangled with
the outdoor fan)
Step
Procedure Points
(R12422)
Hooks
Bell mouth
(R3249)
Lead wire Outdoor fan
SiENBE05-722_A.pdf 141 24/02/2011 14:06:06