SiENBE05-722_A Outdoor Unit - RK(X)S25/35G2V1B
Removal Procedure 161
3.2 Removal of Electrical Box
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure Points
1
Disconnect the 2
connectors for the
reactor.
Preparation
Remove the panels and
disconnect the connector for
the fan motor according to
the “Removal of Outer
Panels / Fan Motor”.
2
Cut the clamps at 2
locations.
3
Disconnect the
connector for the
compressor [S30].
When reassembling, coil the
excessive lead wire and
hang the loop on the hook.
(R9338)
(R9339)
(R9340)
[S30]