Outdoor Unit - RK(X)S25/35G2V1B9 SiENBE05-722_A
178 Removal Procedure
4. Outdoor Unit - RK(X)S25/35G2V1B9
4.1 Removal of Outer Panels / Fan Motor
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1. Appearance features
Take care not to cut your
finger by the fins of the
outdoor heat exchanger.
2. Remove the panels.
The stop valve cover is
united with the shield plate.
When reassembling, make
sure to fit the 5 hooks.
1
Remove the screw of
the stop valve cover.
Pull down the stop
valve cover and remove
it.
DAIKIN
INVERTER
(R7186)
(R118
Stop
valve
cover
(R7188)
Shield plate
Hooks
(R7189)
SiENBE05-722_A.pdf 187 24/02/2011 14:06:13