EasyManua.ls Logo

Daikin FLKS25BAVMB - 2.7 Removal of Compressor

Daikin FLKS25BAVMB
232 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SiENBE05-722_A Outdoor Unit - RK(X)S25/35E2V1B
Removal Procedure 139
7
Release the discharge
pipe thermistor.
Be careful not to lose the clip
for the thermistor.
8
Cut the clamp.
9
Pull out the outdoor
heat exchanger
thermistor.
Be careful not to lose the clip
for the thermistor.
Step
Procedure Points
(R0267)
Discharge pipe thermistor
(R12279)
Clip
(R7221)
(R7222)
Outdoor heat exchanger
thermistor
(R3264)
Clip
Clip
SiENBE05-722_A.pdf 148 24/02/2011 14:06:08