FT15DV2S, FT50/60DSG Si01-501
184 Removal Procedure
2.4 Removal of Electrical Box / PCB / Swing Motor
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1. Removing the front grille.
Parts layout
2. Removing the drip proof
plate.
1
Loosen the screw.
3. Disconnect the indoor
heat exchanger thermistor
and the earth.
Mind that not to lose the clip
for the thermistor.