SiBE121123_A Trial Operation
Trial Operation and Field Settings 222
ARC452 Series
(1) Press the [ON/OFF] button to turn on the system.
(2) Press the both of [TEMP] buttons and the [MODE] button at the same time.
(3) Press the [MODE] button twice.
(
T
appears on the display to indicate that trial operation is selected.)
(4) Press the [MODE] button and select operation mode.
(5) Trial operation terminates in approx. 30 minutes and switches into normal mode. To quit a
trial operation, press the [ON/OFF] button.
ARC433 Series
(1) Press the [ON/OFF] button to turn on the system.
(2) Press the center of the [TEMP] button and the [MODE] button at the same time.
(3) Press the [MODE] button twice.
(
T
appears on the display to indicate that trial operation is selected.)
(4) Press the [MODE] button and select operation mode.
(5) Trial operation terminates in approx. 30 minutes and switches into normal mode. To quit a
trial operation, press the [ON/OFF] button.
(R9675)
(2)
(2) (3) (4)
(1) (5)
(2)
(3)
(2)
(1) (5)
(3)
(2) (3) (4)
(R9663)

Table of Contents

Other manuals for Daikin FTK15JEVM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FTK15JEVM and is the answer not in the manual?

Daikin FTK15JEVM Specifications

General IconGeneral
BrandDaikin
ModelFTK15JEVM
CategoryHeat Pump
LanguageEnglish

Related product manuals