SiBE121123_A Function of RA Indoor Unit
Function and Control 66
1.11 ECONO Operation
Outline Wall Mounted Type, Floor Standing Type
The "ECONO operation" reduces the maximum operating current and the power consumption.
This operation is particularly convenient for energy-saving-oriented users. It is also a major
bonus for those whose breaker capacities do not allow the use of multiple electrical devices and
air conditioners.
It is easily activated from the wireless remote controller by pushing the [ECONO] button.
Detail
When this function is activated, the maximum capacity also decreases.
ECONO operation can only be set when the unit is running. Pressing the [ON/OFF] button
on the remote controller cancels the function.
ECONO operation is available when the unit is in cooling, heating, dry, or automatic
operation and not available in RADIANT or FAN operation.
ECONO operation and POWERFUL operation cannot be used at the same time. The latest
command has the priority.
ECONO Operation
(R9288)
Normal
Maximum during normal operation
Maximum during ECONO operation
Time
Power
consumption
and current

Table of Contents

Other manuals for Daikin FTK15JEVM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FTK15JEVM and is the answer not in the manual?

Daikin FTK15JEVM Specifications

General IconGeneral
BrandDaikin
ModelFTK15JEVM
CategoryHeat Pump
LanguageEnglish

Related product manuals