Removal of Indoor Heat Exchanger Si041143
16 Removal Procedure
2. Remove the indoor heat
exchanger.
1
Detach the indoor unit
from the installation
plate.
2
Unfasten the hook of
the piping fixture at the
back of the indoor unit.
Remove the piping
fixture.
3
Slightly widen the
auxiliary piping.
Step
Procedure Points
(R11365)
(R11366)
Piping fixture
(R11367)
Auxiliary piping