Si041352ED PCBs
Removal Procedure 9
4. PCBs
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step Procedure Points
1. Remove the signal
receiver PCB.
1 Unfasten the 2 hooks of
the shield plate.
2 Open the shield plate
and remove it.
The shield plate has 2 hooks
at the lower part.
3 Remove the screw, and
then the terminal strip.
4 Cut the clamp.
Shield
plate
Hook
(R24480)
Top view
(R9507)
Hook
Right view
(R24483)
Terminal strip
(R24481)
(R24482)
Clamp