Electrical Box Si041352ED
6 Removal Procedure
3. Electrical Box
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step Procedure Points
1 Remove the screw.
The shape of the drip proof
plate varies depending on
the model.
2 Remove the drip proof
plate from the indoor
heat exchanger.
When reassembling, fit the
hook to the indoor heat
exchanger.
3 Remove the screw and
release the earth/
ground wire.
1
2
3
(R9494)
Drip proof plate
(R9496)
(R9495)
1
2
3
(R24477)
Earth/ground wire