SiENBE12-713 Outdoor Unit
Removal Procedure 307
4
Undo the 2 fixing hooks
of the lead wire. Loosen
the 4 screws of the fan
motor.
" When assembling, put the
lead wire through the back of
the motor. (so as not to be
entangled with the propeller
fan)
5
Detach the 4 screws
and 4 rubber vibration
isolators.
Step
Procedure Points
(R3249)
Lead wire Propeller fan