Indoor Heat Exchanger Si041254EE
14 Removal Procedure
4 Slightly pull out the
auxiliary piping.
5 Unfasten the 2 hooks
on the left side.
6 Unfasten the 2 hooks
on the right side.
7 Pull the indoor heat
exchanger to the front
side, unfasten the
hooks completely, and
then remove the indoor
heat exchanger.
Step Procedure Points
Auxiliary piping
(R23430)
Hook
(R13231)
Hook
(R13232)
Indoor heat exchanger
(R2802)