6 | Installation
Installer reference guide
25
FTXP50~71M2V1B + FTXF20~71A2V1B + ATXF50~71A2V1B
Daikin room air conditioner
4P513661-8H – 2019.12
a
a
c
b
a
1
3
2
a Tab
b Protruding part on the top of the cover
c Screw
5 To re-install the cover, first hook the bottom tab onto the electrical wiring
box, and slide the cover into the 2 upper tabs.
6.2.6 To open the service cover
1 Remove 1 screw from the service cover.
2 Pull out the service cover horizontally away from the unit.
a b
a Service cover screw
b Service cover
6.3 Installing the indoor unit
6.3.1 Precautions when installing the indoor unit
INFORMATION
Also read the precautions and requirements in the following chapters:
General safety precautions
Preparation
6.3.2 To install the mounting plate
1 Install the mounting plate temporarily.
2 Level the mounting plate.
3 Mark the centres of the drilling points on the wall using a tape measure.
Position the end of tape measure at symbol " ".
4 Finish the installation by securing the mounting plate on the wall using
M4×25L screws (field supply).