7 | Configuration
Installer reference guide
40
FTXP50~71M2V1B + FTXF20~71A2V1B + ATXF50~71A2V1B
Daikin room air conditioner
4P513661-8H – 2019.12
Model Button
FTXF
a operation indicator
b Indoor unit ON/OFF switch
8 Press the indoor unit ON/OFF switch while the operation indicator is blinking.
Jumper Address
Factory setting 1
After cutting with nippers 2
INFORMATION
If the setting could NOT be completed while the operation lamp was blinking, repeat
the setting process from the beginning.
9 When the setting is complete, press:
Model Button
FTXP
Keep pressed for about 5seconds.
FTXF
Result: The user interface will return to the previous screen.