Specifications EDUS091128
8 Split Type Air Conditioners FTXS-L / FDXS-L Series
60 Hz, 208 - 230 V
Note:
The data are based on the conditions shown in the table below.
Model
Indoor Unit FTXS24LVJU
Outdoor Unit
RXS24LVJU
Cooling Heating
Capacity
Rated (Min.~Max.)
kW 6.30 (2.3 ~ 6.30) 7.44 (2.3 ~ 7.44)
Btu/h 21,500 (7,800 ~ 21,500) 25,400 (7,800 ~ 25,400)
kcal/h 5,400 (1,980 ~ 5,420) 6,400 (1,980 ~ 6,400)
Moisture Removal gal/h (L/h) 1.2 (4.5)
Running Current (Rated) A 8.4 ~ 7.6 10.7 ~ 9.7
Power Consumption Rated
(Min.~Max.)
W 1,720 (570 ~ 1,720) 2,210 (520 ~ 2,210)
Power Factor % 98.4 - 98.4 99.3 - 99.1
COP (Rated) W/W 3.66 (4.04 ~ 3.66) 3.37 (4.40 ~ 3.37)
EER (Rated)
Btu/h·W
12.5 (13.7 ~ 12.5) 11.5 (15.0 ~ 11.5)
Energy Efficiency SEER/HSPF 20.0 10.6
Piping
Connections
Liquid in. (mm) I 1/4 (6.4)
Gas in. (mm) I5/8 (15.9)
Drain in. (mm) I 5/8 (16.0)
Heat Insulation Both Liquid and Gas Pipes
Max. Interunit Piping Length ft (m) 98.4 (30)
Max. Interunit Height Difference ft (m) 65.6 (20)
Chargeless ft (m) 32.8 (10)
Amount of Additional Charge of Refrigerant
oz/ft (g/m) 0.21 (20)
Indoor Unit FTXS24LVJU
Front Panel Color White
Airflow Rate
H
m³/min
(cfm)
18.2 (643) 19.8 (699)
M 14.0 (494) 16.2 (572)
L 9.9 (350) 12.6 (445)
SL 9.3 (328) 11.4 (403)
Fan
Type Cross Flow Fan
Motor Output W 48
Speed Steps 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downward
Air Filter Removable / Washable / Mildew Proof
Running Current (Rated) A 0.57 - 0.51 0.57 - 0.51
Power Consumption (Rated) W 69 - 68 69 - 68
Power Factor (Rated) % 58.2 - 58.0 58.2 - 58.0
Temperature Control Microcomputer Control
Dimensions (H × W × D) in. (mm) 13-3/8 × 41-5/16 × 9-3/4 (340 × 1,050 × 248)
Packaged Dimensions (H × W × D) in. (mm) 16-7/8 x 45-11/16 × 13 (429 x 1,160 × 331)
Weight (Mass) Lbs (kg) 31 (14)
Gross Weight (Gross Mass) Lbs (kg) 46 (21)
Sound Pressure Level (H / M / L / SL) dB(A) 51 / 44 / 37 / 34 48 / 42 / 37 / 34
Sound Power Level dBA 67 64
Outdoor Unit RXS24LVJU
Casing Color Ivory White
Compressor
Type Hermetically Sealed Swing Type
Model 2YC63BXD
Motor Output W 1,920
Refrigerant Oil
Type FVC50K
Charge oz (L) 25.2 (0.750)
Refrigerant
Type R-410A
Charge Lbs (kg) 5.07 (2.3)
Airflow Rate
H
m³/min
(cfm)
54.5 (1,924) 52.5 (1,854)
L 46.0 (1,624) 46.0 (1,624)
Fan
Type Propeller
Motor Output W 66
Running Current (Rated) A 8.1 - 7.3 10.4 - 9.4
Power Consumption (Rated) W 1,651 - 1,652 2,141 - 2,142
Power Factor (Rated) % 98.0 - 98.4 99.0 - 99.1
Starting Current A 10.7
Dimensions (H × W × D) in. (mm) 30-5/16 × 35-7/16 × 12-5/8 (770 × 900 × 320)
Packaged Dimensions (H × W × D) in. (mm) 35-7/16 × 36-7/16 × 15-3/8 (900 × 925 × 390)
Weight (Mass) Lbs (kg) 159 (72)
Gross Weight (Gross Mass) Lbs (kg) 178 (81)
Sound Pressure Level (H / L) dB(A) 52 / 49 52 / 49
Sound Power Level (H) dBA 66 66
Drawing No. 3D075045
Cooling Heating Piping Length
Indoor ; 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB)
Outdoor ; 95°FDB (35°CDB) / 75°FWB (24°CWB)
Indoor ; 70°FDB (21°CDB) / 60°FWB (15.6°CWB)
Outdoor ; 47°FDB (8.3°CDB) / 43°FWB (6°CWB)
25 ft (7.5 m)
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3