3. How to set the different addresses
When2indoorunitsareinstalledinoneroom,
the2wirelessremotecontrollerscanbesetfor
differentaddresses.
1)Removethemetalplateelectricalwiring
cover.
(RefertotheWhen connecting to an HA
system.)
2)Cuttheaddressjumper(JA)ontheprinted
circuitboard.
3)Cuttheaddressjumper(J4)intheremote
controller.
ADDRESS
JC
JA
JB
ADDRESS:JA
EXIST
1
CUT
2
J4
ADDRESS
EXIST
1
CUT 2
J4
4. When connecting to an HA system
(wired remote controller, central remote controller etc.)
1)Removethemetalplateelectricalwiringcover.
(RefertotheRemoval/attachment methods of metal plate electrical wiring covers.)
2)AttachtheconnectioncordtotheS21connectorandpulltheharnessoutthroughthenotchedpartinthegure.
3)Replacetheelectricalwiringcoverasitwas,andpulltheharnessaround,asshowninthegure.
HA connector
(S21)
HA connector
(S21)
Lay the HA cord as
shown in the figure.
•Removal methods of metal plate electrical wiring cover
1)Removethefrontgrille.
2)Removetheelectricalwiringbox.(1screw)
3)Raisethe2upperpartsofthemetalplateelectricalwiringcover,pullthepartsfrontward,andremovethe3tabs.
4)Slidethemetalplateelectricalwiringcoverupwardandremovethe2tabsonthelowerside.
3) Raise the 2 upper parts of the
metal plate electrical wiring cover,
pull the parts frontward, and
remove the 3 tabs.
4) Slide the metal plate electrical wiring
cover upward and remove the 2 tabs on
the lower side.
Ta b
Slide
Slide
Pull
Pull
Slide
Pull
Ta b
01_EN_3P297301-1.indd 5 10/20/2011 2:38:25 PM