Indoor Unit Installation
1. Installing the mounting plate
•Themountingplateshouldbeinstalledonawallwhichcansupporttheweightoftheindoorunit.
1)Temporarilysecurethemountingplatetothewall,makesurethattheplateiscompletelylevel,andmarktheboring
pointsonthewall.
2)Securethemountingplatetothewallwithscrews.
Recommended mounting plate retention spots and dimensions
unit: inch (mm)
Liquid pipe end
Drain hose position
Through the wall hole
ϕ
2-9/16 (
ϕ
65mm)
* The removed pipe port cover can be
kept in the mounting plate pocket.
(Bolt size: 3/8(M10))
Recommended mounting plate
retention spots. (5 spots in all)
(Bolt size: 3/8(M10))
1-3/4
(44.5)
1-13/16
45.5
11-5/8 (295)
4-1/2 (115)
2-1/4 (56.5)
5-13/16 (147.5)
17-11/16 (450)
4-1/16 (103)
15-3/4 (400)
7-7/8 (200)
1-3/4
(44.5)
2-3/8
(60.5)
1-13/16 (45.5)
6-15/16 (175.5)
Keep here the piece cut out
from the unit for piping.
2-5/16
(59.5)
2-3/8
(60)
5-7/8 (149)
10-15/16 (278.5)
1-15/16
(50)
31-1/2 (800)
1-7/16 (36)
Removed pipe port
cover
Mounting plate
Place a leveler on raised tab.
ϕ2-9/16
(ϕ65)
A
Gas pipe end
Use tape measure as
shown.
Position the end of a
tape measure at .
ϕ2-9/16
(ϕ65)
2. Boring a wall hole and installing wall embedded pipe
•Forwallscontainingmetalframeormetalboard,besuretouseawall
embeddedpipeandwallcoverinthefeed-throughholetopreventpossible
heat,electricalshock,orre.
•Besuretocaulkthegapsaroundthepipeswithcaulkingmaterialtoprevent
waterleakage.
1)Boreafeed-throughholeof2-9/16inch(65mm)inthewallsoithasa
downslopetowardtheoutside.
2)Insertawallpipeintothehole.
3)Insertawallcoverintowallpipe.
4)Aftercompletingrefrigerantpiping,wiring,anddrainpiping,caulkpipe
holegapwithputty.
Inside Outside
Caulking
Wall embedded pipe
(field supply)
Wall hole cover
(field supply)
Wall embedded pipe
(field supply)
ϕ2-9/16”
(ϕ65mm)
01_EN_3P297301-1.indd 8 10/20/2011 2:38:29 PM