EasyManua.ls Logo

Daikin FTXS20K2V1B - Note for Multi System

Daikin FTXS20K2V1B
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
29
Note for Multi System
Multisystemhasoneoutdoorunitconnectedtomultipleindoorunits.
Selecting the operation mode
With the priority room setting present but
inactive or not present.
Whenmorethanoneindoorunitisoperating,priorityisgivento
therstunitthatwasturnedon.
Inthiscase,settheunitsthatareturnedonlatertothesame
operationmodeastherstunit.
Otherwise,theywillenterthestandbystate,andtheOPERATION
lampwillash:thisdoesnotindicatemalfunction.
NOTE
Notes on operation mode for multi system
• COOL,DRYandFANoperationmaybeusedatthesametime.
• AUTOoperationautomaticallyselectsCOOLoperationorHEAToperationbasedontheroomtemperature.
Therefore,AUTOoperationisavailablewhenselectingthesameoperationmodeasthatoftheroomwiththerstunittobeturnedon.
CAUTION
• Normally,theoperationmodeintheroomwheretheunitisrstrunisgivenpriority,butthefollowingsituationsareexceptions,sopleasekeep
thisinmind.
IftheoperationmodeoftherstroomisFANoperation,thenusingHEAToperationinanyroomafterthiswillgiveprioritytoHEAToperation.In
thissituation,theairconditionerrunninginFANoperationwillgoonstandby,andtheOPERATIONlampwillash.
With the priority room setting active.
Refertopriorityroomsettingonthenextpage.
NIGHT QUIET mode (Available only for COOL operation)
NIGHTQUIETmoderequiresinitialprogrammingduringinstallation.Pleaseconsultyourretailerordealerforassistance.
NIGHTQUIETmodereducestheoperationnoiseoftheoutdoorunitduringthenighttimehourstopreventannoyanceto
neighbors.
• TheNIGHTQUIETmodeisactivatedwhenthetemperaturedrops5°Cormorebelowthehighesttemperaturerecordedthatday.Therefore,
whenthetemperaturedifferenceislessthan5°C,thisfunctionwillnotbeactivated.
• NIGHTQUIETmodereducesslightlythecoolingefciencyoftheunit.
OUTDOOR UNIT QUIET operation
RefertoOUTDOORUNITQUIEToperation.
Page19
With the priority room setting present but inactive or not present.
WhenusingtheOUTDOORUNITQUIEToperationfeaturewiththemultisystem,setallindoorunitstoOUTDOORUNIT
QUIEToperationusingtheirremotecontrollers.
WhenclearingOUTDOORUNITQUIEToperation,clearoneoftheoperatingindoorunitsusingtheirremotecontroller.
HoweverOUTDOORUNITQUIEToperationdisplayremainsontheremotecontrollerforotherrooms.
Werecommendyoureleaseallroomsusingtheirremotecontrollers.
With the priority room setting active.
Refertopriorityroomsettingonthenextpage.
A room B room
C room D room
Outdoor unit
01_EN_3P297033-1.indd 29 10/12/2011 2:15:27 PM

Other manuals for Daikin FTXS20K2V1B

Related product manuals