EasyManua.ls Logo

Daikin FTXS20K2V1B - LED ON OUTDOOR UNIT PCB

Daikin FTXS20K2V1B
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
41
Troubleshooting
LED ON OUTDOOR UNIT PCB
3MXS, 4MXS, 5MXS series
GREEN RED
MICROCOMPUTER
NORMAL
MALFUNCTION
DETECTION
LED-A LED1 LED2 LED3 LED4 LED5 DIAGNOSIS
NORMAL CHECKINDOORUNIT
HIGHPRESSUREPROTECTORWORKEDORFREEZE-UPIN
OPERATINGUNITORSTAND-BYUNIT
*OVERLOADRELAYWORKEDORHIGHDISCHARGEPIPE
TEMPERATURE
FAULTYCOMPRESSORSTART
INPUTOVERCURRENT
*THERMISTORORCTABNORMALITY
HIGHTEMPERATURESWITCHBOX
HIGHTEMPERATUREATINVERTERCIRCUITHEATSINK
*OUTPUTOVERCURRENT
*REFRIGERANTSHORTAGE
LOWVOLTAGETOMAINCIRCUITORMOMENTARYVOLTAGE
LOSS
REVERSINGSOLENOIDVALVESWITCHINGFAILURE
FANMOTORFAULT
[NOTE1]
POWERSUPPLYFAULTOR[NOTE2]
NOTE:TheLED5isonlyavailableinthe5Mseries.
GREEN NORMALLYFLASHING
RED NORMALLYOFF
ON
FLASHING
OFF
IRRELEVANT
LED ON OUTDOOR UNIT PCB
2MXS series
GREEN
MICROCOMPUTERNORMAL
LED-A DIAGNOSIS
NORMAL CHECKINDOORUNIT
[NOTE1]
POWERSUPPLYFAULTOR[NOTE2]
GREEN NORMALLYFLASHING
ON
FLASHING
OFF
NOTE
• Turnthepoweroffandthenonagain.IftheLEDdisplayrecurs,theoutdoorunitPCBisfaulty.
• Diagnosismarked
*Donotapplytosomecases.Fordetails,refertotheserviceguide.
01_EN_3P297033-1.indd 41 10/12/2011 2:15:41 PM