5 English
Preparation before Installation
3.
How to set the different addresses
When two indoor units are installed in one room,
the two wireless remote controllers can be set
for different addresses.
1) Remove the metal plate electrical wiring
cover.
(Refer to the Removal/attachment methods
of metal plate electrical wiring covers.)
2) Cut the address jumper (JA) on the printed
circuit board.
3) Cut the address jumper in the remote
controller.
4.
When connecting to an HA system
(wired remote controller, central remote controller etc.)
1) Remove the metal plate electrical
wiring cover.
(Refer to the Removal/
attachment methods of metal
plate electrical wiring covers.)
2) Attach the connection cord to the
S21 connector and pull the
harness out through the notched
part in the figure.
3) Replace the electrical wiring cover
as it was, and pull the harness
around, as shown in the figure.
Removal methods of metal plate electrical wiring cover
1) Remove the front grille. (3 screws)
2) Remove the electrical wiring box. (1 screw)
3) Remove the 4 tabs, and pull and disconnect the metal plate electrical wiring cover from the single insertion mouth.
ADDRESS
JC
JA
JB
ADDRESS:JA
EXIST
1
CUT
2
1
2
Jumper
ADDRESS
EXIST
CUT
HA connector
(S21)
Mount the edge of the metal
plate electrical wiring cover
passing under the tabs.
Insert the metal plate electrical
wiring cover into the insertion
mouth.
3) Remove the 4 tabs, and pull and disconnect the
metal plate electrical wiring cover from the
single insertion mouth.
Screw
2) Remove the electrical
wiring box. (1 screw)
01_EN_3P248445-1B.fm Page 5 Thursday, August 5, 2010 9:46 AM