SiENBE04-401A Outdoor Unit / RK(X)H-C, ARK(X)H-C, R(Y)N-C
Removal Procedure 205
2
Pull the partition plate
upward to remove.
3
When restoring the
partition plate, fit the
hook into the bottom
frame.
Step Procedure Points
(R4058)
(R4059)

Table of Contents