SiENBE04-401A Outdoor Unit / RK(X)S-C, ARK(X)S-C
Removal Procedure 183
2.5 Removal of Four Way Valve
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1. Remove the peripheries.
Remove the four
way valve and the
sheets of putty so as
not to burn them.
1
Remove the terminal
cover.
Be careful so as not to burn
the compressor terminals or
the name plate.
Make a note.
2
Loosen the screw of the
four way valve coil.
Terminal
cover
Red (U)
Yellow (V)
Blue (W)