SiENBE04-401A Wiring Diagrams
Appendix 227
2. Wiring Diagrams
2.1 Indoor Units
FTK(X)S20/25/35CVMB(9)(8), ATK(X)S20/25/35CVMB(9), FTK(X)S20/25/35CAVMB
ATK(X)S20/25/35DAVMB
FTN20/25/35CVMB9, FTYN20/25/35CVMB9
LED1
PCB2
PCB3
H1P
INTELLIGENT-
EYE SENSOR
RECEIVER
SIGNAL
LED2
H2P
S1W
WIRELESS
REMOTE
CONTROLLER
LED3
H3P
R1T
S27
t
°
S36 S35
S26
S32
R2T
t
°
S21
PCB1
(
FU
C70
TERMINAL FOR
CENTRALIZED CONTROL
:
:
:
S6
FUSE
M
PROTECTIVE EARTH
RUNNING CAPACITOR
M1S
S7
indoor
)
S1
1
t
°
M
M1F
C70
140
°
C
TRANSMISSION
CIRCUIT
3.15A
Fu
H1P~H3P :PILOT LAMP
M1F :FAN MOTOR
M1S :SWING MOTOR
PCB1~PCB3:PRINTED CIRCUIT BOARD
R1T~R2T :THERMISTOR
S1~S36 :CONNECTOR
S1W :OPERATION SWITCH
X1M :TERMINAL STRIP
H2
H3
H1
GRN
WHT
RED
BLK
/
YLW
X1M
2
3
1
NOTE THAT OPERATION WILL
RESTART AUTOMATICALLY IF
THE MAIN POWER SUPPLY IS
TURNED OFF AND THEN BACK
ON AGAIN.
CAUTION
FIELD WIRING.
2
3
1
outdoor
3D033599G
LED1
PCB2
H1P
RECEIVER
SIGNAL
CONTROLLER
LED2
H2P
S1W
WIRELESS
REMOTE
LED3
H3P
R1T
S27
t
°
S26
S32
R2T
t
°
S21
PCB1
(
FU
C70
TERMINAL FOR
CENTRALIZED CONTROL
: FUSE
: PROTECTIVE EARTH
S6
: RUNNING CAPACITOR
M
M1S
S7
indoor
)
S1
1
t
°
M
M1F
C70
140
°
C
TRANSMISSION
CIRCUIT
3.15A
Fu
M1S
X1M
S1W
M1F
H1P~H3P
S1~S32
PCB1~PCB2
R1T~R2T
H2
H3
H1
: PILOT LAMP
: FAN MOTOR
: SWING MOTOR
: PRINTED CIRCUIT BOARD
: THERMISTOR
: CONNECTOR
: OPERATION SWITCH
: TERMINAL STRIP
GRN
WHT
RED
BLK
/
YLW
X1M
2
3
1
NOTE THAT OPERATION WILL
THE MAIN POWER SUPPLY IS
TURNED OFF AND THEN BACK
RESTART AUTOMATICALLY IF
ON AGAIN.
CAUTION
FIELD WIRING.
2
3
1
outdoor
3D038710B

Table of Contents