9
■ To set the clock
1. Press “CLOCK button”.
is displayed.
blinks.
2. Press “TIMER setting button” to
set the clock to the present time.
Holding down “ ” or “ ” button rapidly
increases or decreases the time display.
3. Press “CLOCK button”.
blinks.
■ Turn the breaker ON
• Turning ON the breaker opens the flap, then
closes it again. (This is a normal procedure.)
NOTE
■
Tips for saving energy
•
Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps save energy.
•
Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases the cooling (heating)
effect.
•
Clogged air filters cause inefficient operation and waste energy. Clean them once in about every two weeks.
■
Please note
•
The air conditioner always consumes 15-35 watts of electricity even while it is not operating.
•
If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn the breaker
OFF.
•
Use the air conditioner in the following conditions.
•
Operation outside this humidity or temperature range may cause a safety device to disable the system.
1, 3
2
Recommended temperature setting
For cooling: 26°C – 28°C
For heating: 20°C – 24°C
Mode Operating conditions If operation is continued out of this range
COOL
Outdoor temperature: 10 to 46°C
Indoor temperature: 18 to 32°C
Indoor humidity: 80% max.
•
A safety device may work to stop the operation.
•
Condensation may occur on the indoor unit and drip.
HEAT
Outdoor temperature: –10 to 20°C
Indoor temperature: 10 to 30°C
•
A safety device may work to stop the operation.
DRY
Outdoor temperature: 10 to 46°C
Indoor temperature: 18 to 32°C
Indoor humidity: 80% max.
•
A safety device may work to stop the operation.
• Condensation may occur on the indoor unit and drip.
01_EN_3P232468-8.fm Page 9 Wednesday, June 4, 2008 10:33 AM