Troubleshooting by Remote Controller Si20-701_B
109
Troubleshooting
Note:
∗1 Capacity is factory setting in the data IC on the PCB.
A capacity setting adaptor that matches the capacity
of the unit is required in the following case.
If the indoor unit PCB installed at the factory is for
some reason changed at the installation site, the
capacity will not be contained in the replacement
PCB.
If you connect a capacity setting adaptor to a PCB in
which the capacity is memorized, the capacity setting
for the PCB will become the capacity setting of the
adaptor. (Priority of capacity setting adaptor)
Is the
capacity setting
adaptor plugged into
the connector of the
indoor unit
PCB?
NO
YES
Plug a capacitor
setting adaptor
that matches the
capacity of the
unit into the
connector. (∗1)
Turn OFF the power
supply and turn the power
ON.
Caution
Be sure to turn off the power switch before
connecting or disconnecting connectors, or parts
may be damaged.
The error
is displayed again.
YES
Replace the
indoor unit PCB.
External factor
(Noise, etc.).
NO

Table of Contents

Other manuals for Daikin FUY71FJV1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FUY71FJV1 and is the answer not in the manual?

Daikin FUY71FJV1 Specifications

General IconGeneral
BrandDaikin
ModelFUY71FJV1
CategoryAir Conditioner
LanguageEnglish

Related product manuals