EasyManuals Logo

Daikin FUY71FJV1 User Manual

Daikin FUY71FJV1
501 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #123 background imageLoading...
Page #123 background image
Si20-701_B Troubleshooting by Remote Controller
116
Troubleshooting
Note:
∗1. Pull out and insert the connecter once and check it is
absolutely connected.
Is the
connector
between indoor
unit PCB and fan PCB
accurately
connected?
(∗1)
NO
YES
Connect the
connector
accurately.
Under
above field
setting mode,
installation position
is "
01".
NO
YES
NO
The error is
displayed again.
Replace the
indoor unit PCB.
Connect the connecter
and turn ON the power
again.
Caution
Be sure to turn off the power switch before
connecting or disconnecting connectors, or parts
may be damaged.
Confirm the condition of
transmission on indoor
unit PCB using field
setting mode. (∗2)
YES
Replace the fan
PCB.
Connect it and
operate (It is
possible to have
a cause, such as
instantaneous
blackout)

Table of Contents

Other manuals for Daikin FUY71FJV1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FUY71FJV1 and is the answer not in the manual?

Daikin FUY71FJV1 Specifications

General IconGeneral
BrandDaikin
ModelFUY71FJV1
CategoryAir Conditioner
LanguageEnglish

Related product manuals