EasyManuals Logo

Daikin FUY71FJV1 User Manual

Daikin FUY71FJV1
501 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #265 background imageLoading...
Page #265 background image
Si20-701_B Troubleshooting by Remote Controller
258
2: “Pressure Sensor”, pressure / voltage characteristics
table.
Detected pressure PH (MPa)
Output voltage V
-0.5
-0.5
0
0.5
1.0
2.0
3.0
1.5
2.5
0.5 1.5 2.5 3.501234
V
DC
PH
PH= 1.38V-0.69
PH: Detected pressure (MPa)
V : Output Voltage (V)

Table of Contents

Other manuals for Daikin FUY71FJV1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FUY71FJV1 and is the answer not in the manual?

Daikin FUY71FJV1 Specifications

General IconGeneral
BrandDaikin
ModelFUY71FJV1
CategoryAir Conditioner
LanguageEnglish

Related product manuals