SiBE041101 Wiring Diagrams
Appendix 254
2. Wiring Diagrams
2.1 Indoor Unit
FTXS20/25/35/42/50J2V1B
2.2 Outdoor Unit
RK(X)S20/25/35J2V1B
1
FU1
X1M
PCB1
PCB3
S46
S49
2
H1
F1U
BLK
11
BLK
1
LED1
3
BLK
3.15A
H1P
WHT
~
OUTDOOR
2
BLK
C102 V1
BLK
LED2
RED
3
H2
MR10
BLK
GRN
H2P
BLK
FIELD WIRING.
BLK
LED3
GRN
C101
BLK
/
H3
YLW
H3P
99
BLK
CAUTION
FG
SW1
S21
S1
HA
7
RED
RTH1BZ
R1T
4
BLU
S25
MS
BRN
BLK
11
PCB4
ORG
BLK
3~
S26
BLK
1
WHT
S41
S47 S32
44
BLK
M1F
16 4121121431311027359611815
BLK
BLK
BLK
BLK
BLK
PNK
PNK
PNK
BLU
BLU
BLU
RED
RED
RED
ORG
ORG
ORG
YLW
YLW
YLW
S48
PCB2
1
3
INDOOR
R2T
MSW MSWMSW
M2SM1S M3S
INTELLIGENT EYE
SENSOR
WIRELESS
REMOTE
CONTROLLER
SIGNAL
RECEIVER
TRANSMISSION
CIRCUIT
NOTE THAT OPERATION WILL RESTART
AUTOMATICALLY IF THE MAIN POWER SUPPLY
IS TURNED OFF AND THEN BACK ON AGAIN.
BZ : BUZZER
C101, C102 : CAPACITOR
FG : FRAME GROUND
F1U : FUSE
H1P~H3P : PILOT LAMP
MR10 : MAGNETIC RELAY
M1F : FAN MOTOR
M1S~M3S : SWING MOTOR
PCB1~PCB4 : PRINTED CIRCUIT BOARD
R1T, R2T : THERMISTOR
S1~S49 : CONNECTOR
SW1 : OPERATION SWITCH
V1 : VARISTOR
X1M : TERMINAL STRIP
:PROTECTIVE EARTH
3D058246D
FIELD WIRING.
indoor
MRM20
N=2
WHT
IPM1
FU3
Z3C
X1M
DB1
L1R
HR1
20A
HR2
AC1
L1
~+
BRN
+
L1
BLK
1
MRM10
AC2
+
HN3
V2
WHT
2
2N
DB2
HN2
C5
HA2HA1
S
+
BLU GRY
~
RED
3
3
~+
HL3
C119
HL2
+
V3
ORG
C6
FU1
L
Q1
~
MR30
3.15A
1
WHT
1
V1
BLK
N
PCB2
DB3
BLK
FU2
BLK
3.15A
GRN/YLW
SA1
S11
~+
S10
BLK
BLK
E1
W
V
U
BLK
IPM2
BLK
99
~
+
BLK
MR30_B
E2
MR30_A
MRCW
GRN
BLU
RED
S70
YLW
S100S50
Z2C
S90
S20
S40
X11A
PCB1
S80
13
3
1
1
2
4
10 1311
1
12
7
16
1126
N=2
GRN
outdoor
BLK
WHT
WHT
NOTE
BLU
BLK
BRN
BRN
RED
YLW
BLK
GRY
BLU
RED
BLU
BLU
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLU
RED
BRN
4
ORG
1
ORG
WHT
YLW
WHT
YLW
21
31
Y1R
S80
Z1C
X12A
MS
M
S110
N=3
V
3~
Q1L
IN CASE OF
U
R1T R3TR2T
W
SW1
MS
BLK
BLK
COOLING ONLY
Y1E
(OUTDOOR) (DISCHARGE)
3~
M1F
M1C
TYPE
PCB3
(CONDENSER)
_
_
_
_
_
_
_
_
1.REFER TO THE NAMEPLATE FOR THE POWER REQUIREMENTS.
C5, C6, C119
: CAPACITOR
DB1, DB2, DB3
: DIODE BRIDGE
FU1, FU2, FU3
: FUSE
IPM1, IPM2
: INTELLIGENT POWER MODULE
L
: LIVE
L1
: COIL
L1R
: REACTOR
M1C
: COMPRESSOR MOTOR
M1F : FAN MOTOR
MRCW, MR30, MRM10, MRM20 : MAGNETIC RELAY
N
: NEUTRAL
Q1L
: OVERLOAD PROTECTOR
PCB1, PCB2, PCB3
: PRINTED CIRCUIT BOARD
S10, S11, S20, S40, S50
S70, S80, S90, S100, S110
HL3, HN3, X11A, X12A
: CONNECTOR
R1T, R2T, R3T : THERMISTOR
SA1
: SURGE ARRESTER
SW1
: FORCED OPERATION SWITCH
V1, V2, V3
: VARISTOR
X1M
: TERMINAL STRIP
Y1E
: ELECTRONIC EXPANSION VALVE COIL
Y1R
: REVERSING SOLENOIDE VALVE COIL
Z1C, Z2C, Z3C
: FERRITE CORE
: PROTECTIVE EARTH
3D065704B

Table of Contents

Other manuals for Daikin J-Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin J-Series and is the answer not in the manual?

Daikin J-Series Specifications

General IconGeneral
BrandDaikin
ModelJ-Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals