Installation and Maintenance Manual IM 970-2
Group: Applied Air Handling
Part Number: 920102421-20
Date: May 2017
Maverick
®
I
Heating & Cooling
Models MPSA03 – A05, 14 SEER
Models MPSH03 – H05, 15 SEER
3 to 5 Tons
R-410A Refrigerant

Questions and Answers

  • K
    Kristy RayAug 3, 2025
    Why is my Daikin Maverick I MPS A03C unit not running?
    • S
      shannon30Aug 3, 2025
      Your Daikin Air Conditioner might not be running due to several reasons: * The power could be off, or there might be a loose electrical connection. Check for the correct voltage at the compressor contactor in the control box. * The thermostat might be out of calibration or set too high. Try resetting it. * A contactor could have failed. Check for 24 volts at the contactor coil; replace it if the contacts are open. * Blown fuses or a defective transformer could be the issue. Replace the fuses. * The high-pressure control might be open (if provided). Check the wiring, replace the transformer, and reset. Note that the high-pressure control opens at 450 PSIG. * The low voltage wiring may be damaged. Replace the thermostat wiring.
  • N
    nbeasleyAug 12, 2025
    What to do if my Daikin Air Conditioner has insufficient cooling?
    • J
      John KennedyAug 12, 2025
      If your Daikin Air Conditioner isn't cooling enough, consider these potential causes: * The unit may be improperly sized. Recalculate the load. * There might be improper airflow. Check that it's approximately 400 CFM per ton. * The refrigerant charge could be incorrect. Charge it according to the procedure attached to the unit's service panel. * There may be air, non-condensables, or moisture in the system. Recover the refrigerant, evacuate, and recharge, adding a filter drier. * The voltage might be incorrect. Ensure the voltage at the compressor terminals is within 10% of the rating plate volts when the unit is operating.
  • T
    Tyler TownsendAug 22, 2025
    What to do if the condenser fan runs, but the compressor doesn’t, in my Daikin Maverick I MPS A03C?
    • J
      Jeremy BradyAug 23, 2025
      If the condenser fan in your Daikin Air Conditioner is running but the compressor isn’t, here are a few things to check: * There might be a loose connection. Check for the correct voltage at the compressor and tighten all connections. * The compressor could be stuck, grounded, have an open motor winding, or an open internal overload. Wait at least 2 hours for the overload to reset. If it's still open, replace the compressor. * There could be a low voltage condition. At the compressor terminals, the voltage must be within 10% of the rating plate volts when the unit is operating. You can also add start kit components.

Summary

INTRODUCTION

Hazardous Information Messages

Lists crucial safety warnings, including dangers of unauthorized components and proper ventilation.

MECHANICAL INSTALLATION

General

General installation guidelines, including adherence to codes and recommended publications.

Location Considerations

Factors to consider when locating the unit, including environmental protection and service access.

Clearances

Minimum required clearances for proper unit performance and serviceability.

Gas Supply, Condensate Drain and Piping

Procedures for connecting gas supply, condensate drain, and piping according to codes.

ELECTRICAL INSTALLATION

Power Supply

Requirements for connecting the unit to the electrical power supply, including voltage and circuit protection.

PHYSICAL DATA

DIMENSIONAL DATA

PERFORMANCE DATA

CONTROLS AND OPERATION

Furnace Section Controls and Ignition System

Explanation of the furnace control sequence and ignition system operation.

Manual Reset Overtemperature Control

Description of the safety control and warnings against tampering.

MAINTENANCE

TROUBLESHOOTING

Table 28: Cooling Troubleshooting Chart

A chart listing common cooling issues, possible causes, and remedies.

Furnace Troubleshooting Guide

A flowchart to diagnose and resolve furnace operational problems.