Installation and Maintenance Manual IM 970-2
Group: Applied Air Handling
Part Number: 920102421-20
Date: May 2017
Maverick
®
I
Heating & Cooling
Models MPSA03 – A05, 14 SEER
Models MPSH03 – H05, 15 SEER
3 to 5 Tons
R-410A Refrigerant

Questions and Answers

  • A
    Amy WilliamsAug 8, 2025
    Why is my Daikin Maverick I MPS A05C unit not running?
    • K
      katrinafrazierAug 8, 2025
      Your Daikin Air Conditioner might not be running due to several reasons: * The power could be off, or there might be a loose electrical connection. Check for the correct voltage at the compressor contactor in the control box. * The thermostat might be out of calibration or set too high. Try resetting it. * A contactor could have failed. Check for 24 volts at the contactor coil; replace it if the contacts are open. * Blown fuses or a defective transformer could be the issue. Replace the fuses. * The high-pressure control might be open (if provided). Check the wiring, replace the transformer, and reset. Note that the high-pressure control opens at 450 PSIG. * The low voltage wiring may be damaged. Replace the thermostat wiring.
  • I
    icarterAug 19, 2025
    What to do if my Daikin Air Conditioner has insufficient cooling?
    • A
      Alyssa RayAug 19, 2025
      If your Daikin Air Conditioner isn't cooling enough, consider these potential causes: * The unit may be improperly sized. Recalculate the load. * There might be improper airflow. Check that it's approximately 400 CFM per ton. * The refrigerant charge could be incorrect. Charge it according to the procedure attached to the unit's service panel. * There may be air, non-condensables, or moisture in the system. Recover the refrigerant, evacuate, and recharge, adding a filter drier. * The voltage might be incorrect. Ensure the voltage at the compressor terminals is within 10% of the rating plate volts when the unit is operating.
  • M
    Martin FletcherAug 28, 2025
    What to do if the condenser fan runs, but the compressor doesn’t, in my Daikin Maverick I MPS A05C?
    • M
      Ms. Yolanda JohnsonAug 28, 2025
      If the condenser fan in your Daikin Air Conditioner is running but the compressor isn’t, here are a few things to check: * There might be a loose connection. Check for the correct voltage at the compressor and tighten all connections. * The compressor could be stuck, grounded, have an open motor winding, or an open internal overload. Wait at least 2 hours for the overload to reset. If it's still open, replace the compressor. * There could be a low voltage condition. At the compressor terminals, the voltage must be within 10% of the rating plate volts when the unit is operating. You can also add start kit components.

Summary

Introduction

Hazardous Information Messages

Critical safety warnings regarding unauthorized components, combustion, and installation location.

Mechanical Installation

Location Considerations

Guidance on selecting an appropriate installation location to ensure proper operation and longevity.

Outside Slab Installation

Specific instructions for installing the unit on an outdoor slab.

Rigging and Roof Curb

Instructions and details for rigging the unit and installing roof curbs.

Gas Supply, Condensate Drain and Piping

Procedures for connecting gas supply, condensate drain, and piping, including safety precautions.

Adjusting or Checking Furnace Input

Procedures for adjusting and checking furnace input pressure and flow rates.

Electrical Installation

Power Supply

Safety precautions and procedures for connecting the unit's power supply.

Wiring Diagrams

Physical Data

Unit Capacity and Physical Data

Detailed specifications for cooling and heating performance and physical attributes.

Dimensional Data

Unit Dimensions MPS A03 C - A05 C

Detailed physical dimensions and access locations for MPS A03C-A05C units.

Performance Data

System Performance - Standard Efficiency

Gross system performance data for standard efficiency models under various conditions.

MPS A04 C, 4 Tons Gas Heat Performance

Gross system performance data for MPS A04C 4-ton units with gas heat.

MPS A05 C, 5 Tons Gas Heat Performance

Gross system performance data for MPS A05C 5-ton units with gas heat.

System Performance - High Efficiency

Gross system performance data for high efficiency models under various conditions.

MPS H04 C, 4 Tons Gas Heat Performance

Gross system performance data for MPS H04C 4-ton units with gas heat.

MPS H05 C, 5 Tons Gas Heat Performance

Gross system performance data for MPS H05C 5-ton units with gas heat.

Airflow Performance

Airflow performance data for MPS A03C-A05C models at different static pressures.

Airflow Performance - 3 Ton

Airflow performance data for 3-ton models at various voltages and static pressures.

Accessories

Economizers

Features and types of economizers available for 3-5 Ton units.

Controls and Operation

Furnace Section Controls and Ignition System

Description of the integrated direct spark ignition control and operating sequence.

Operating Instructions

General operating instructions, including safety warnings for gas leaks.

Maintenance

System Charge Charts

Charts for determining the correct refrigerant charge for MPS A03C cooling.

Blower Motor Speed Taps

Instructions for changing blower motor speeds using speed tap blocks.

Troubleshooting

Cooling Troubleshooting Chart

Table of common cooling system symptoms, possible causes, and recommended remedies.

Furnace Troubleshooting Guide

Flowchart to diagnose issues related to the furnace ignition and operation.

Furnace Troubleshooting Guide Continued

Continuation of the furnace troubleshooting guide, covering burner and system operation.

Warranty

Daikin Maverick I MPS A05C Specifications

General IconGeneral
BrandDaikin
ModelMaverick I MPS A05C
CategoryAir Conditioner
LanguageEnglish