15
Quick Reference Table of Maintenance
Remove the parts for maintenance in numerical order.
For details on removing and attaching each part, see
Page 17. .
1
Front panel
2
Pre lter
3
UNIT1
(Plasma ioniser)
4
UNIT2
(Streamer unit)
The  gure above shows
UNIT1 after the opposing
pole plates are removed.
If it gets dirty
Wipe
About once every 2 weeks
Vacuum cleaner
Rinse with water
If the “UNIT1”
lamp lights
Soak, drain and dry
Wipe
Once every 3 months or if
the “UNIT2” lamp lights
Soak, drain and dry
Wipe
Wipe off the dirt with a cloth
slightly moistened with water.
In the case of heavy dirt, wipe it
off with a cloth moistened with
neutral detergent.
Do not use hard brushes, etc.
Use a vacuum cleaner to
remove the dust from the
pre lter, and wash it with water.
In the case of heavy dirt, wash
the pre lter with a soft brush or
neutral detergent and dry it well
in the shade.
Dry the pre lter completely before
using it because the “UNIT1” lamp
may light up if any water drops
remain on the pre lter.
Use a vacuum cleaner to remove the dust.
Soak in lukewarm water or water. (About 1 hour)
Dry throughly after soaking.
Care and Cleaning
Page 19, 20.
Ionised wire
Ionising frame
Opposing pole plates
NOTE
When detergent is used, wipe the detergent off the surface to
prevent any residue.
Do not dry the pre lter in a place exposed to direct sunlight.
Do not use hot water with a temperature of 50°C or higher for
cleaning the parts.
Do not dry the parts over a  re.
It may cause discolouration or deformation of the parts and the
parts may become unusable.
Do not use gasoline, benzene, thinner, scouring powder,
kerosene, alcohol, etc.
(Cracking, electric shock or  re may occur.)
Do not wash the main unit with water.
(Electric shock,  re or malfunction may occur.)
WARNING
Before performing maintenance, stop the unit and disconnect the power plug. (It may cause electric shock or injury.)
Disconnecting the unit while it is operating causes the auto-restart function to automatically resume operation when the power plug is
connected next time.
WARNING
01_EN_3P276413-4F.indd 15 8/1/2012 11:29:43 AM