Installation and Maintenance IM 972-2
Group: Applied Air Handling
Part Number: IM 972
Date: November 2018
Maverick
®
I
Commercial Packaged Rooftop Systems
Heating & Cooling
Models MPS015B - MPS025B
15 to 25 Tons
R-410A Refrigerant

Table of Contents

Questions and Answers

  • D
    Denise MillerJul 25, 2025
    What to do if my Daikin MPS020B Heat Pump unit will not run?
    • J
      Julian MartinJul 25, 2025
      If your Daikin Heat Pump unit won't run, there are several potential causes: * A power issue: check for correct voltage at the compressor contactor in the control box, or replace blown fuses. * Thermostat calibration: try resetting the thermostat if it's set too high. * Contactor failure: check for 24 volts at the contactor coil and replace it if the contacts are open. * Transformer issue: check the wiring and replace the transformer if it's defective. * High pressure control: reset it, noting that it opens at 450 PSIG. See also High Head Pressure Remedy. * Damaged low voltage wiring: replace the thermostat wiring.
  • E
    Emily MooreAug 5, 2025
    Why is my Daikin Heat Pump providing insufficient cooling?
    • M
      Misty NguyenAug 5, 2025
      Insufficient cooling in your Daikin Heat Pump can stem from several issues: * Incorrect unit size: recalculate the load to ensure the unit is appropriately sized. * Improper airflow: verify airflow is approximately 400 CFM per ton. * Refrigerant issues: charge the unit per the procedure attached to the service panel, or recover refrigerant to evacuate and recharge, adding a filter drier if there's air, non-condensables, or moisture in the system. * Voltage problems: ensure voltage at the compressor terminals is within 10% of the rating plate volts when the unit is operating.
  • L
    Lisa PerryAug 14, 2025
    What to do if the condenser fan runs, but the compressor doesn’t in my Daikin Heat Pump?
    • A
      Aaron WelchAug 14, 2025
      If the condenser fan runs but the compressor doesn’t in your Daikin Heat Pump, consider these possibilities: * Loose connection: check for correct voltage at the compressor and tighten all connections. * Compressor issue: wait at least 2 hours for overload to reset. If still open, replace the compressor, as it may be stuck, grounded, have an open motor winding, or an open internal overload. * Low voltage: at compressor terminals, voltage must be within 10% of rating plate volts when unit is operating. You may need to add start kit components.

Summary

Introduction

Safety Precautions

Manufacturer's warnings and notices for safe installation and operation.

Mechanical Installation

Pre-Installation Requirements

Critical checks and conditions to meet before unit installation.

Ducting and Connections

Instructions for ductwork, gas piping, and condensate drain connections.

Electrical Installation

Power Supply and Wiring

Guidelines for power supply, branch circuit disconnects, and field wiring.

Accessories

Controls and Operation

Furnace Controls and Operation

Overview of furnace control system and normal operating sequences.

Maintenance

System Charge Charts

Charts for determining correct refrigerant charge based on operating conditions.

Troubleshooting

Cooling Troubleshooting

Guides for diagnosing and resolving common cooling system issues.

Furnace Troubleshooting

Flowcharts to diagnose and fix furnace operational problems.

Daikin MPS020B Specifications

General IconGeneral
ModelMPS020B
CategoryHeat Pump
Cooling Capacity (kW)2.0
Heating Capacity (kW)2.5
Power Supply220-240V, 50Hz
RefrigerantR32
Operating Temperature Range (Heating)-15°C to 24°C