Daikin Navigator WWV - Field Wiring Diagram for Single Point Power; Power Source Connections Diagram

Daikin Navigator WWV
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21
IOM 1264-4
WWW.DAIKINAPPLIED.COM
ELECTRICAL
Figure 16: Field Wiring Diagram - Single Point Power
4-20 mA
DEMAND LIMIT
(BY OTHERS)
0-10V
CONDENSER TOWER SPEED
(BY OTHERS)
_
_
+
+
EA1
** USE DRY CONTACTS ONLY, SEE NOTE 2
IF EXTERNAL ALARM IS USED, REMOVE
LEAD 544B BETWEEN M5 TERMINALS 1 & 2
TIME
CLOCK
OFF
MANUAL
ON
AUTO
115
VAC
F120
T1
F120
M5
REMOTE
SWITCH
(BY OTHERS)
M5
M5
M5
M5
M5
M5
M5
EXTERNAL
ALARM
N
N
120 VAC
120 VAC
M5
MQ
M5
MQ
CHWR1
(BY OTHERS)
EVAP. WATER PUMP RELAY
120VAC @ 0.25AMP MAX
17
17
ALARM OUTPUT
EVAP. WATER
PUMP RELAY No. 1
(BY OTHERS)
3 PHASE
POWER
SOURCE
POWER BLOCK
OR
DISCONNECT SWITCH
NOTE: ALL FIELD WIRING TO BE
INSTALLED AS NEC CLASS 1 WIRING
SYSTEM WITH CONDUCTOR RATED
600 VOLTS
TO
COMPRESSOR(S)
OR CIRCUIT 1
CIRCUIT BREAKER
(BY OTHERS)
12
MQ
MQ
17
EARTH
GROUND
Q12
(BY OTHERS)
ALARM OUTPUT
120VAC @ 0.25AMP MAX
(4-20 mA)
LWT RESET
(BY OTHERS)
M5
+
N
120 VAC
M5
MQ
CHWR1
(BY OTHERS)
COND. WATER PUMP RELAY
120VAC @ 0.25AMP MAX
17
COND. WATER
PUMP RELAY No. 1
(BY OTHERS)
N
120 VAC
M5
MQ
COOLING TOWER 1
RELAY No. 1
(BY OTHERS)
(BY OTHERS)
COOLING TOWER RELAY
120VAC @ 0.25AMP MAX
N
120 VAC
M5
MQ
17
COOLING TOWER 2
RELAY No. 1
(BY OTHERS)
(BY OTHERS)
COOLING TOWER RELAY
120VAC @ 0.25AMP MAX
MODE SWITCH
M5
M5
1
2
3
5
4
17
7
8
11
12
13
14
15
16
17
25
24
CONTACTS RATED FOR 24 VOLTS AC AND 8mA.
DO NOT APPLY VOLTAGE FROM EXTERNAL SOURCE
IF REMOTE SWITCH IS USED,
REMOVE MECHANICAL JUMPER
BETWEEN M5 TERMINALS 24 & 25.
TO/FROM BAS
(CUSTOMER
CONNECTION)
CLA
CLB
CONNECT TO GROUND
AT ONE END ONLY.
TO/FROM BAS
(CUSTOMER
CONNECTION)
(+)
(-)
REF
CONNECT TO GROUND
AT ONE END ONLY.
TO/FROM BAS
(CUSTOMER
CONNECTION)
REF
(-)
(+)
TO/FROM BAS
(CUSTOMER
CONNECTION)
CONNECT TO GROUND
AT ONE END ONLY.
(503)
(503)
(503)
(503)
COMMUNICATION
OPTION
WHEN SELECTED
LONMARK
BACNET-MSTP
BACNET WITH IP
MODBUS
NOTE:
1) ALL FIELD WIRING TO BE
INSTALLED AS NEC CLASS 1 WIRING
SYSTEM WITH CONDUCTOR RATED
600 VOLTS.
2)**=USE "DRY CONTACTS" ONLY.
DO NOT SUPPLY FIELD POWER TO
THIS CIRCUIT.
3)DO NOT SUPPLY FIELD POWER TO
24VAC OR 120VAC CONTROL CIRCUITS.
** USE DRY CONTACTS ONLY, SEE NOTE 2
0-10V
TOWER BYPASS VALVE POSITION
(BY OTHERS)
_
+
M5
M5
18
19
N
120 VAC
M5
MQ
CHWR2
(BY OTHERS)
EVAP. WATER PUMP RELAY
120VAC @ 0.25AMP MAX
17
EVAP. WATER
PUMP RELAY No. 2
(BY OTHERS)
N
120 VAC
M5
MQ
CHWR2
(BY OTHERS)
COND. WATER PUMP RELAY
120VAC @ 0.25AMP MAX
17
COND. WATER
PUMP RELAY No. 2
(BY OTHERS)
9
10
BACKUP
CHILLER
29
28
M5
M5
BC1
FOR RAPID
RESTORE OPTION
ONLY
** USE DRY CONTACTS ONLY, SEE NOTE 2
T1
L3 T3
L1
PANEL
T2L2
GND
GND
GND
(519)
(538)
(538)
(514)
(517)
(523)
(521)
(520)
(524)
(525)
(515)
(529)
(532)
(533)
(556)