Si01-406 Wiring Diagrams
Appendix 191
FTY25CVMA / FTY35CVMA
2.2 Outdoor Units
R25CV1A
LED1
PCB2
H1P
RECEIVER
SIGNAL
CONTROLLER
LED2
H2P
S1W
REMOTE
WIRELESS
LED3
H3P
R1T
t˚
S27 S26
S32
R2T
t˚
S21
PCB1
(
CENTRALIZED CONTROL
)
FU : FUSE
C70 : RUNNING CAPACITOR
TERMINAL FOR
: PROTECTIVE EARTH
S6
M
M1S
S7
indoor
S1
S1
1~
t˚
M
M1F
C70
140˚C
TRANSMISSION
CIRCUIT
3.15A
Fu
S1~S32 : CONNECTOR
R1T~R2T : THERMISTOR
M1F : FAN MOTOR
M1S : SWING MOTOR
H1P~H3P : PILOT LAMP
X1M : TERMINAL STRIP
S1W : OPERATION SWITCH
PCB1~PCB2 : PRINTED CIRCUIT BOARD
H2
H3
H1
GRN
WHT
RED
BLK
/
YLW
X1M
2
3
1
NOTE THAT OPERATION WILL
THE MAIN POWER SUPPLY IS
TURNED OFF AND THEN BACK
RESTART AUTOMATICALLY IF
ON AGAIN.
CAUTION
FIELD
2
3
1
WIRING.
outdoor
3D038710B
POWER SUPPLY
220V-240V
~ 50Hz
TO INDOOR UNIT
2
3
1
N
L
TFU
76ºC
X2M
X1M
N
2
3
L
1
GRN
BLK
YLW
BLK
GRN
YLW
BLK
L : LIVE
N : NEUTRAL
TFU : THERMAL FUSE
K1M : COMPRESSOR RELAY
M1C : COMPRESSOR MOTOR
C11R
,
C12R : RUNNING CAPACITOR
Q1CL
RED
BLK
3.15A
BLK
F1U
RED
WHT
BLU
BLK
14
4
6
A2
BLK
K1M
13
3
5
F1U : FUSE
M1F : FAN MOTOR
Q1CL : OVERCURRENT
OVERLOAD PROTECTOR
A1
X1M
,
X2M : TERMINAL STRIP
BRN
C12R
C11R
: PROTECTIVE EARTH
YLW
BLK
BLU
RED
RED
WHT
3D024713B
S
M
C
1~
1~
M
M
140ºC
M1C
M1F