EasyManua.ls Logo

Daikin R35DV1 - Page 113

Daikin R35DV1
268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Check Function Si01-501
104 Service Diagnosis
Check Method 2
1. Enter the diagnosis mode.
Press the 3 buttons (TEMP,TEMP, MODE) simultaneously.
The digit of the number of tens blinks.
Try again from the start when the digit does not blink.
2. Press the TEMP button.
Press TEMP or TEMP and change the digit until you hear the sound of “beep” or “pi pi”.
3. Diagnose by the sound.
“ pi ” : The number of tens does not accord with the error code.
“ pi pi ” : The number of tens accords with the error code.
“ beep ” : The both numbers of tens and units accord with the error code. (
See 7.)
4. Enter the diagnosis mode again.
Press the MODE button.
(R4272)
(R4273)
(R4274)
(R4275)

Table of Contents

Other manuals for Daikin R35DV1

Related product manuals