Si01-501 Others
Others 235
1.2 Jumper Settings
1.2.1 When Two Units are Installed in One Room
How to set the different addresses.
When two indoor units are installed in one room, the two wireless remote controllers can be
set for different addresses.
PCB in the indoor unit
FT25/35DVM, FT25/35DSG, FT09/13DV2S
Remove the front grille. (2 screws)
Remove the electrical wiring box. (1 screw)
Remove the metal plate electrical wiring cover. (3
tabs)
Cut the address jumper JA on the printed circuit
board.
FT50/60DSG, FT15DV2S
Remove the front grille. (3 screws)
Remove the electrical box (1-screw).
Remove the metal plate. (4 tabs)
Cut the address jumper JA on control PCB.
Wireless remote controller
Cut the jumper J4.
1.2.2 Jumper Setting
Screw
Address
JA
Address
JA
EXIST
1
CUT 2
tab(3)
Metal
cover
PCB
Electrical
wiring box
(R4788)
Screw
Address
JA
Address
JA
EXIST
1
CUT 2
tab(4)
Metal
cover
PCB
Electrical
wiring box
(R4789)
Wireless
remote
controller
AddressJ4
CUT
EXIST
1
2
J4
Jumper
(On indoor control PCB)
Function When connected
(factory set)
When cut
JC Power failure
recovery function
Auto re-start Unit does not resume operation
after recovering from a power
failure. Timer ON-OFF settings
are cleared.
JB Fan speed setting
when compressor is
OFF on thermostat.
Fan speed setting ;
Remote controller
setting
Fan rpm is set to “0”
<Fan stop>