keyPad/dIsPlay Menu sTruCTure
www.DaikinApplied.com 123 IM 893-10 • ROOFPAK SINGLEZONE UNITS
Alarm Log
Log Count: xx Clr Log= No
+/-Alarm 1: Alarm Type
+/-Alarm 2: Alarm Type
+/-Alarm 10: Alarm Type
+/-Alarm 50: Alarm Type
Analog Input Status
MCB Al1= XXXXXXXX
MCB Al2= XXXXXXXX
MCB Al3= XXXXXXXX
Universal I/O Status
MCB X1= XXXXXXXX EMC X1= XXXXXXXX
MCB X2= XXXXXXXX EMC X2= XXXXXXXX
MCB X3= XXXXXXXX EMC X3= XXXXXXXX
MCB X4= XXXXXXXX EMC X4= XXXXXXXX
MCB X5= XXXXXXXX EMC X5= XXXXXXXX
MCB X6= XXXXXXXX EMC X6= XXXXXXXX
MCB X7= XXXXXXXX EMC X7= XXXXXXXX
MCB X8= XXXXXXXX EMC X8= XXXXXXXX
EMA X1= XXXXXXXX EMD X1= XXXXXXXX
EMA X2= XXXXXXXX EMD X2= XXXXXXXX
EMA X3= XXXXXXXX EMD X3= XXXXXXXX
EMA X4= XXXXXXXX EMD X4= XXXXXXXX
EMA X5= XXXXXXXX EMD X5= XXXXXXXX
EMA X6= XXXXXXXX EMD X6= XXXXXXXX
EMA X7= XXXXXXXX EMD X7= XXXXXXXX
EMA X8= XXXXXXXX EMD X8= XXXXXXXX
EMB X1= XXXXXXXX EME X1= XXXXXXXX
EMB X2= XXXXXXXX EME X2= XXXXXXXX
EMB X3= XXXXXXXX EME X3= XXXXXXXX
EMB X4= XXXXXXXX EME X4= XXXXXXXX
EMB X5= XXXXXXXX EME X5= XXXXXXXX
EMB X6= XXXXXXXX EME X6= XXXXXXXX
EMB X7= XXXXXXXX EME X7= XXXXXXXX
EMB X8= XXXXXXXX EME X8= XXXXXXXX
Digital Input Status
MCB DI1= ____________
MCB DI2= ____________
MCB DI3= ____________
MCB DI4= ____________
MCB DI5= ____________
MCB DI6= ____________
EMD DLA1= __________
Digital Output Status
MCB DO1= __________ EMC DO1= __________
MCB DO2= __________ EMC DO2= __________
MCB DO3= __________ EMC DO3= __________
MCB DO4= __________ EMC DO4= __________
MCB DO5= __________ EMC DO5= __________
MCB DO6= __________ EMC DO6= __________
MCB DO7= __________ EMD DO1= __________
MCB DO8= __________ EMD DO2= __________
MCB DO9= __________ EMD DO3= __________
MCB DO10= __________ EMD DO4= __________
EMA DO1= __________ EMD DO5= __________
EMA DO2= __________ EMD DO6= __________
EMA DO3= __________ EME DO1= __________
EMA DO4= __________ EME DO2= __________
EMA DO5= __________ EME DO3= __________
EMA DO6= __________ EME DO4= __________
EMB DO1= __________ EME DO5= __________
EMB DO2= __________ EME DO6= __________
EMB DO3= __________
EMB DO4= __________
EMB DO5= __________
EMB DO6= __________
Alarm Conguration
ALARM LIMITS
Hi Disch Temp= 170°F
Lo Disch Temp= 40°F
Hi Return Temp= 120°F
ALARM OUT CONFIG
Faults= Fast
Problems= Slow
Warnings= Off
ALARM DELAYS
Frz Delay Time= 30s
LP Delay= 2s
LP Comp Delay= 5s
Air Flw Ing=120s
Sens Alm Dly= 30s
Temp AlmDly= 30s
ALARM CONFIG
Emerg Stop= ManClr
4
3, 4 See connection on page 125

Table of Contents

Other manuals for Daikin RDT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin RDT and is the answer not in the manual?

Daikin RDT Specifications

General IconGeneral
BrandDaikin
ModelRDT
CategoryAir Conditioner
LanguageEnglish

Related product manuals