IM 893-10 • ROOFPAK SINGLEZONE UNITS 150 www.DaikinApplied.com
roofToP equIPMenT WarranTy regIsTraTIon forM
Daikin IM 893-4 127
Rooftop Equipment Warranty Regist. Form
Warranty Registration Form (continued)
VI. GAS BURNER CHECK, TEST, & START
Specifications:
Refer to IM 684 Modulating Forced Draft Gas Fired Furnace and IM 685 SuperMod Forced Draft Gas Fired Furnace
A. (Gas) Furnace model no. _____________________
B. (Gas) Burner model no. _____________________ Serial no. ___________________
C. (Gas) Type firing: _________Single _________Stage 2 _________Stage Modulation
D. (Gas) Rated firing rate: _________________ MBH input
E. (Gas) Altitude:______________________ ft. above sea level
F. Is there a circulating tank? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes No N/A
VII. GAS BURNER CHECK, TEST, & START
A. Input:________________________________ CFH
B. Gas pressure at burner: ________________inches w.c.
C. CO
2
: __________________________ %
D. CO
2
: __________________________ %
E. Pilot flame only: ______________ microamps (steady at low fire)
F. Pilot Tap-gas pressure: _________________inches w.c.
G. Motor only/burner: FLA __________________ running amps
H. High limit control OK? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes No N/A
I. Flame safeguard: ________________ microamps
J. Flame failure shutoff: _______________ seconds
K. Airswitch OK? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes No N/A
L. High Gas Pressure Switch OK? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes No N/A
M. Low Gas Pressure Switch OK? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes No N/A
N. Main Gas Valve Close-off OK? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes No N/A
VIII. Design Flow Calibration
A. Verify power is supplied to the MicroTech III unit controller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes No N/A
B. Verify that the shipping screws have been removed from the measuring station vane. . . . . . . . . . . . . . . . . . . . . . . . . . Yes No N/A
C. Examine station for shipping damage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes No N/A
D. Refer to IM 893 or IM 987 for Design Flow Setup Procedure and Calibration Procedure . . . . . . . . . . . . . . . . . . . . . . .
E. Record Level Positions after final calibration.
LH Level Position: ______________
RH Level Position: ______________
Note: This is viewed in the MicroTech III Controller, in the Min OA setup menu.
IX. Have all electronic or electrical controls been checked, adjusted, and tested for proper operation per the
installation and maintenance bulletins?
Yes No N/A
X. MAINTAINING MICROTECH CONTROL PARAMETER RECORDS
After the unit is checked, tested, and started and the final control parameters are set, record the final settings. Keep these records on file and
update whenever changes to the control parameters are made. Keeping a record facilitates any required analysis and troubleshooting of the
system operation and facilitates restoration after a controller replacement.
Signature: ______________________________________________________ Startup date:____________________________________
RETURN COMPLETED FORM TO:
Daikin Warranty Department, 13600 Industrial Park Boulevard, Minneapolis, MN 55441
Please list any additional comments that could affect the operation of this unit; e.g., shipping damage, failed components, adverse installation
applications, etc., on a separate sheet and attach to this form.

Table of Contents

Other manuals for Daikin RDT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin RDT and is the answer not in the manual?

Daikin RDT Specifications

General IconGeneral
BrandDaikin
ModelRDT
CategoryAir Conditioner
LanguageEnglish

Related product manuals