SiUS39-602
Troubleshooting 111
Part 6
Troubleshooting
1. Troubleshooting by Remote Controller ...............................................114
1.1 The INSPECTION / TEST Button ........................................................114
1.2 Self-diagnosis by Wired Remote Controller .........................................115
1.3 Self-diagnosis by Wireless Remote Controller..................................... 116
1.4 Operation of the Remote Controller’s Inspection /
Test Operation Button .......................................................................... 119
1.5 Remote Controller Service Mode .........................................................120
1.6 Remote Controller Self-Diagnosis Function.........................................122
2. Troubleshooting by Indication on the Remote Controller....................127
2.1 A0 Indoor Unit: Error of External Protection Device ........................... 127
2.2 A1 Indoor Unit: PC Board Defect ........................................................ 128
2.3 A3” Indoor Unit: Malfunction of Drain Level Control System (S1L)......129
2.4 A6 Indoor Unit: Fan Motor (M1F) Lock, Overload .............................. 131
2.5 A7 Indoor Unit: Malfunction of Swing Flap Motor (MA).......................132
2.6 A9 Indoor Unit: Malfunction of Moving Part of
Electronic Expansion Valve (20E)........................................................134
2.7 AF” Indoor Unit: Drain Level above Limit ............................................. 136
2.8 AJ” Indoor Unit: Malfunction of Capacity Determination Device..........137
2.9 C4” Indoor Unit: Malfunction of Thermistor (R2T) for
Heat Exchanger ................................................................................... 138
2.10 C5” Indoor Unit: Malfunction of Thermistor (R31T, R32T) for
Gas Pipes ............................................................................................ 139
2.11 C9” Indoor Unit: Malfunction of Thermistor (R1T) for Suction Air ........140
2.12 CJ” Indoor Unit: Malfunction of Thermostat Sensor in
Remote Controller................................................................................ 141
2.13 E1” Outdoor Unit: PC Board Defect...................................................... 142
2.14 E3Outdoor Unit: Actuation of High Pressure Switch.......................... 143
2.15 E4” Outdoor Unit: Actuation of Low Pressure Sensor.......................... 144
2.16 E5” Compressor Motor Lock (INV Compressor) .................................. 145
2.17 E6” Compressor Motor Overcurrent/Lock (STD Compressor)............. 146
2.18 E7” Malfunction of Outdoor Unit Fan Motor.......................................... 147
2.19 E9” Outdoor Unit: Malfunction of Moving Part of
Electronic Expansion Valve (Y1E, Y2E, Y3E)......................................149
2.20 F3” Outdoor Unit: Abnormal Discharge Pipe Temperature.................. 151
2.21 F6” Refrigerant Overcharged...............................................................152
2.22 H7” Abnormal Outdoor Fan Motor Signal............................................. 153
2.23 H9” Outdoor Unit: Malfunction of Thermistor for Outdoor Air
(R1T).................................................................................................... 154
2.24 J2” Current Sensor Malfunction ..........................................................155
2.25 J3Outdoor Unit: Malfunction of Discharge Pipe Thermistor
(R31~32T)............................................................................................ 156
2.26 J4” Malfunction of Heat Exchanger Gas Pipe Thermistor
(R81, 82T) ............................................................................................ 157