EasyManua.ls Logo

Daikin RMKS112EV1A - Page 20

Daikin RMKS112EV1A
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Outdoor Unit Si181095
18 Removal Procedure
8 Disconnect the brazed
part of the solenoid
valve.
Note:
Do not use a metal saw for
cutting pipes by all means
because the sawdust comes
into the circuit.
When withdrawing the pipes,
be careful not to pinch them
firmly with pliers. The pipes
may get deformed.
Provide a protective sheet or
a steel plate so that the
brazing flame cannot
influence peripheries.
Step
Procedure Points
(R12983)
Solenoid valve for
hot gas bypass
Solenoid valve for unloading
(R12984)