Preparation Before Operation
Tips for saving energy
•
Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps save energy.
•
Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases the cooling (heating) effect.
Operation range
If the temperature or the humidity is beyond the following conditions, safety devices
may work and the air conditioner may not operate, or sometimes, water may drop from the indoor unit.
DB: Dry bulb temperature WB: Wet bulb temperature
The setting temperature range of the remote controller is 16°C to 32°C.
Useful Information
Observe the following precautions to ensure the system operates properly.
Recommended temperature setting
For cooling 26 to 28 °C
For heating 20 to 24 °C
Cooling
INDOOR
OUTDOOR TEM-
PERATURE
TEMPERATURE HUMIDITY
DB 21 to 32 °C
80% or below
(Long time operation in a humid-
ity over 80% may cause conden-
sation on the unit and dripping.)
DB –5 to 46 °C
WB 14 to 25 °C
Heating
**–20~–15°CWB: Range for operation
–15~15.5°CWB: Range for continuous operation
INDOOR
TEMPERATURE
OUTDOOR
TEMPERATURE
DB 15 to 27 °C
DB –20 to 21 °C**
WB
–20 to 15.5 °C
**
•
Set the room temperature appropriately.
Take care not to cool or heat the room excessively.
Adjust the temperature so that everyone in the room is comfortable.
•
Ventilate the room from time to time.
Be sure to ventilate the room after using the air conditioner for a long time.
• Do not leave the door or window open.
The air will be released, and the effect of cooling/heating
will be reduced.
• Do not allow direct sunshine to enter the room
during
the cooling operation.
Hang a curtain or blind to the window to prevent direct sunshine.
• Keep televisions, radios or stereo equipment at least
1 meter from the indoor unit or remote controller.
Otherwise, picture
disturbance or
noise may result.
• Use flow direction adjustment skillfully.
Cold air collects toward the floor and hot air collects toward
the ceiling. Therefore, for cooling, set the air flow horizontally,
and for heating, set the air flow downward. Also, set
the air flow so that it does not blow directly on your body.
26-28˚C
during
cooling
20-24˚C
during
heating
•
Turn off the power when the air conditioner is not
used for a long time.
With the power on, the air conditioner will consume
sev
eral to several tends of watts of power (∗1)
NOTE
∗1The power consumption while the equipment is stopped
varies with the type of outdoor unit, etc. Consult your
dealer for further details on power consumption.
•
Do not use and room heater under the indoor unit.
Heat may deform the indoor unit of suction grille.
• Do not place things near the air outlet or air inlet.
Such obstacles may lower the performance
of the air
conditioner or make it st
op.
•
When the display shows “ ” (TIME TO CLEAN
AIR FILTER), refer to the instruction manual of the
indoor unit, and clean the air filter.
• Use timer operation effectively.
It takes time for the room temperature to
reach the set temperature. Therefore, use
timer operation to start the air conditioner
ahead of time.
OFF
7