    Marcus WebsterAug 12, 2025
    What to do if Daikin Air Conditioner operation stopped suddenly but operation lamp is on?
    • K
      Kathleen TurnerAug 12, 2025
      If your Daikin Air Conditioner stops suddenly but the operation lamp is still on, it's likely due to a large voltage fluctuation that triggered the system's protection mechanism. The air conditioner should automatically resume operation in about 3 minutes.
  • M
    Michael ChavezAug 16, 2025
    How to fix Daikin RXYMQ5BVM that does not operate at all?
    • R
      rojasvictoriaAug 16, 2025
      If your Daikin Air Conditioner does not operate at all, check if the fuse has blown or if the breaker has tripped. Turn the power on with the breaker switch in the off position. Do not turn the power on with the breaker switch in the trip position and contact your dealer. After power recovers, try operating the air conditioner again.
  • R
    Rebecca WillisAug 20, 2025
    Why does Daikin RXYMQ5BVM Air Conditioner operation not start soon?
    • E
      Edward SimmonsAug 20, 2025
      This delay is to protect your Daikin Air Conditioner. The microcomputer needs time to prepare for operation, so you should wait approximately 5 minutes, or up to 10 minutes.
  • J
    jandersonAug 23, 2025
    Why hot air does not flow out soon after Daikin Air Conditioner power supply is turned on?
    • M
      Michelle CookAug 23, 2025
      The Daikin Air Conditioner is likely warming up. Allow about 1 minute for the system to reach a certain temperature before it starts discharging air.
  • R
    Rebecca GarrisonAug 27, 2025
    What to do if Daikin RXYMQ5BVM heating operation stops suddenly and a flowing sound is heard?
    • C
      caseydavisAug 27, 2025
      The system is removing frost from the outdoor unit. Wait approximately 3 to 8 minutes, but no more than 10 minutes, for the Daikin Air Conditioner to complete this process.
  • L
    Lynn JonesAug 31, 2025
    Why warm air exits Daikin RXYMQ5BVM Air Conditioner unit even though it is off?
    • E
      Elizabeth BergerAug 31, 2025
      If multiple units are operating on the same system, refrigerant will flow through the stopped units, causing warm air to exit even when the unit is off.
  • H
    hendersonrandySep 4, 2025
    Why a “Zeen” sound is heard immediately after Daikin RXYMQ5BVM Air Conditioner power supply is turned on?
    • V
      Victoria NormanSep 4, 2025
      This sound comes from the electronic expansion valve inside the indoor unit as it starts working. The noise should reduce within about one minute.
  • J
    Jason HodgeSep 7, 2025
    What causes a continuous low “Shah” sound when Daikin RXYMQ5BVM is in cooling operation or at a stop?
    • D
      Dawn HunterSep 7, 2025
      This sound is normal. It is the drain pump (optional accessory) operating.

Summary

Read Before Operation

Safety Precaution

Covers essential safety instructions, warnings, and cautions to prevent injury, electric shock, and fire hazards.

System Component Identification

Details the names and functions of the air conditioner's indoor and outdoor units, and the remote controller.

Installation and Setup Guidance

Provides advice on selecting installation sites, energy-saving tips, and initial operational preparations.

Optimal Usage Advice

Offers tips for efficient operation, including temperature settings, ventilation, and avoiding obstructions.

Air Conditioner Operations

Core Mode Operations

Step-by-step instructions for operating the unit in cooling, heating, and fan-only modes using the remote.

Humidity Control Function

Explains the 'Program Dry' mode for dehumidifying the air without over-cooling the room.

Airflow Direction Control

Guides users on how to adjust the airflow direction and flap movement for optimal comfort.

Setting the Auto Off Timer

Details the procedure for setting the automatic shut-off timer for the air conditioner.

Multi-Controller Setup

Describes the process for designating a master controller in systems with multiple remote controls.

Troubleshooting and Maintenance

Identifying Normal Sounds

Explains common sounds that may occur during operation, clarifying normal vs. problematic noises.

Pre-Service Troubleshooting Guide

Lists common issues and checks users can perform before contacting a service technician.

Model Specifications

Provides technical specifications, including cooling/heating capacities and blowing methods for different models.

Post-Purchase Services

Outlines cautions regarding self-repair and recommends professional periodic maintenance.

Daikin RXYMQ5BVM Specifications

General IconGeneral
CategoryAir Conditioner
ModelRXYMQ5BVM
Cooling Capacity14.0 kW
Heating Capacity16.0 kW
Power Supply3 Phase, 380-415V, 50Hz
Energy Efficiency Ratio (Cooling)3.21
RefrigerantR410A
Indoor Unit Dimensions (WxHxD)845 x 285 x 200 mm
Indoor Unit Weight9 kg