2 | Components
Service manual
116
FTXF20~71A + FTXF20~25B + FTXF20~42C + ATXF20~71A + ATXF20~42C
+ RXF20~71A + RXF20~60B + RXF20~42C + ARXF20~71A + ARXF20~42C
Split Sensira R32
ESIE18-12E – 2021.02
ab c
a Cover
b Screw
c Swing flap motor
2 Disconnect the connector from the swing flap motor.
3 Remove the screw from the swing flap motor.
4 Remove the swing flap motor from the swing flap.
5 To install the swing flap motor, see "2.12.2Repair procedures"[4115].
To install the swing flap motor
1 Install the swing flap motor in the correct location on the swing flap.
ab c
a Cover
b Screw
c Swing flap motor
2 Install and tighten the screw to fix the swing flap motor.
3 Connect the connector to the swing flap motor.
4 Install the cover.
Is the problem solved? Action
Yes No further actions required.
No Return to the troubleshooting of the
specific error and continue with the
next procedure.

Table of Contents