Service manual
Split Stylish R32
CTXA15A(W)(S)(T)
CTXA15B(B)(S)(T)
FTXA20A(W)(S)(T)
FTXA20B(B)(S)(T)
FTXA25A(W)(S)(T)
FTXA25B(B)(S)(T)
FTXA35A(W)(S)(T)
FTXA35B(B)(S)(T)
FTXA42A(W)(S)(T)
FTXA42B(B)(S)(T)
FTXA50A(W)(S)(T)
FTXA50B(B)(S)(T)
RXA42A
RXA50A
RXA20A
RXA25A
RXA35A
RXA42B
RXA50B

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Daikin Stylish Series and is the answer not in the manual?

Daikin Stylish Series Specifications

General IconGeneral
Energy EfficiencyA+++ (depending on model)
Sound Pressure Level19 dB(A) - 50 dB(A) (depending on model)
Sound Power Level (Heating)32 dB(A) - 62 dB(A) (depending on model)
Noise Level (Indoor Unit)19 dB(A) - 50 dB(A) (depending on model)
RefrigerantR32
Power Supply220-240 V, 50 Hz
Wi-Fi ControlYes
ColorWhite
Features3D Airflow

Summary

Troubleshooting

Error based troubleshooting

Troubleshooting guide for specific error codes and their causes.

Symptom based troubleshooting

Troubleshooting guide based on observed system symptoms.

Components

4-way valve

Checking and repair procedures for the 4-way valve.

Compressor

Procedures for checking and repairing the compressor unit.

Expansion valve

Checking and repair procedures for the electronic expansion valve.

Indoor unit PCB

Checking and repair procedures for the indoor unit printed circuit board.

Inverter PCB

Checking and repair procedures for the inverter PCB.

Main PCB

Detailed checks and repair procedures for the main printed circuit board.

Outdoor unit fan motor

Checking and repair procedures for outdoor unit fan motors.

Thermistors

Checking and repair procedures for refrigerant and other thermistors.

Third party components

Refrigerant circuit

Procedures for checking the refrigerant circuit's condition and charge.