EasyManuals Logo

Daikin Stylish Series User Manual

Daikin Stylish Series
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
1 | Troubleshooting
Service manual
9
(C)(F)TXA15~50A(W)(S)(T) + (C)(F)TXA15~50B(B)(S)(T) + RXA42+50A +
RXA20~35A + RXA42+50B
Split Stylish R32
ESIE18-03C – 2020.02
1.5.2 A5-00 – Freeze-up protection / heating peak cut control
Trigger Effect Reset
During cooling operation,
indoor heat exchanger
temperature is below 0°C
(freeze‑up protection
control).
Unit will stop operating. Automatic reset when
temperature is within
range.
During heating operation,
indoor heat exchanger
temperature is above
65°C (heating peak‑cut
control).
To solve the error code
INFORMATION
It is recommended to perform the checks in the listed order.
1 Check for objects near the indoor unit that may block the airflow. See
"3.3External factors"[4140].
Possible cause: Airflow of the indoor unit is blocked.
2 Clean the air filter. See "4Maintenance"[4142].
Possible cause: Faulty or dirty air filter.
3 Clean the indoor unit heat exchanger. See "4Maintenance"[4142].
Possible cause: Dirty indoor unit heat exchanger.
4 Perform a check of the indoor unit heat exchanger thermistor. See
"2.18Thermistors"[4119].
Possible cause: Faulty indoor unit heat exchanger thermistor.
5 Perform a check of the indoor unit PCB. See "2.8Indoor unit PCB"[471].
Possible cause: Faulty indoor unit PCB.
INFORMATION
If all procedures listed above have been performed and the problem is still present,
contact the helpdesk.
1.5.3 A6-00 – Indoor unit fan motor abnormality
Trigger Effect Reset
The rotation speed of the
fan motor is NOT
detected while the output
voltage to the fan is at its
maximum.
Unit will stop operating. Power reset via the
outdoor unit.
To solve the error code
INFORMATION
It is recommended to perform the checks in the listed order.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin Stylish Series and is the answer not in the manual?

Daikin Stylish Series Specifications

General IconGeneral
Energy EfficiencyA+++ (depending on model)
Sound Pressure Level19 dB(A) - 50 dB(A) (depending on model)
Sound Power Level (Heating)32 dB(A) - 62 dB(A) (depending on model)
Noise Level (Indoor Unit)19 dB(A) - 50 dB(A) (depending on model)
RefrigerantR32
Power Supply220-240 V, 50 Hz
Wi-Fi ControlYes
ColorWhite
Features3D Airflow